Bose AmPlus 100
Brand: Bose
Model: AmPlus 100
Technical data[edit]
- Output power
- stereo
65 W per channel into 4 ohms
- 50 W into 8 Ohm
- mono
- 70 V, bridged: 100 W into 49 ohms
- 100 V, bridged: 100 W into 98 ohms
- 70 V/4 ohms: 50 W @ 70 V output into 98 ohms
- 65 W @ channel 2 output into 4 ohms
- 100 V/4 ohms: 50 W @ 70 V output into 196 ohms
- 65 W @ channel 2 output into 4 ohms
- Input Sensitivity:
- 315 mV required to fully drive the amplifier in any mode of operation.
- Input attenuation: 0 dB to -8
- Input/Output Configurations:
- 1. 2 channels (stereo)
- 2. mono at 4 ohm load
3. mono at 70V/100V load 4. dual mono (1 source/2 zones)
- 5. channel 1: 70 V/100 V; channel 2: 4 ohms
- Input impedance:
- 32 kOhm, balanced
11 kOhm, unbalanced
- Output impedance (line output): 600 ohms
- Distortion (line output): 0.1%
- Frequency response (active equalizer bypassed)
4 ohm outputs: 40 Hz - 16 kHz, ±1 dB 70 V outputs: 60 Hz - 16 kHz, ±1 dB
- Total harmonic distortion at rated output power
4-Ohm Outputs: 1% (40 Hz - 16 kHz) 70 V outputs: 1% (60 Hz - 16 kHz)
- Hum and noise
Line outputs: 92 dB
- Power amplifier outputs: 80 dB below maximum output power at 4-ohm load
- LED indicator
- Power supply: front panel
- Controls:
- Input 1 and 2
- Input attenuation
- Volume remote control
- Bass level adjustment 1 and 2
- Input mode switch
Amplifier Mode Switch
- Front panel power switch
- Power input
120 V AC, 50/60 Hz, 350 W max 220-240 V AC, 50/60 Hz, 350 W max
- Operating temperature range (passively cooled, top and bottom vents): -10° C to +50° C
- Special features:
- Volume remote control.
- Mute on/off switch
- Clipping detector and limiter
- Short circuit protection
DC voltage protection Thermal limiting Stable at reactive load
- High frequency interference protection
- Internationally approved as safe by UL (6500), CSA (E65) and IEC (65); meets EMC CE standards.
Remarks[edit]
Other models in the same series: