Difference between revisions of "Luxman M-05"

m (nicht vorlagenkonform)
Line 3: Line 3:
 
== LUXMAN M-05
 
== LUXMAN M-05
  
ENDSTUFE
+
    * Continual effective output: A class 105W + 105W (8 Ω, 20Hz - 20kHz both ch simultaneous operation)
 
+
    * BTL connection effective output: AB class 400W (to 105W A class, 8 Ω, 20Hz - 20kHz)
Erscheinungsdatum : 1985
+
    * Total height harmonic wave distortion factor: 0.008% (8 Ω, both ch simultaneous operation) 0.01% (4 Ω, both ch)
 
+
    * Cross modulation distortion factor: 0.008% (8 Ω, 60Hz: 7kHz = 4: 1)
Leistungsdaten : 2 X 105 WATT CLASS A
+
    * Frequency characteristic: 10 - 100, 000Hz (- 0.5 dB)
 
+
    * Entry sensitivity: 750mV
KLirrfaktor 0,005 %
+
    * Input impedance: DIRECT - IN 300k Ω, ATT - IN 45k Ω
 
+
    * Signal-noise ratio: 120 dB (IHF - A revision)
Übertragunsbereich : 10 - 100000 KHZ
+
    * Attachment: The line phase sensor BTL connected SW sub sonic filter SW (15Hz)
 
+
      which the polarity of terminal signal OFF SW 3 step change FAN SW
Gräuschspannung : > 120 db
+
      power source for the peak hold attaching peak meter (meter OFF SW
 
+
      The line phase sensor BTL connected SW sub sonic filter SW (15Hz)
Abmessungen : 460 mm x 437 MM x 210 mm ==
+
      which can manage the polarity of 3 step change FAN SW power sources -
 
+
      6 dB/oct entry worm rise feature pre- heat Entry worm rise feature pre- heat feature
Gewicht : 40 Kg
+
    * Protection network: DC drift detection speaker protection network overcurrent detection
 
+
      amplifier protection network temperature detection amplifier
Verkaufspreis : 8000 DM--[[Benutzer:80.135.249.100|80.135.249.100]] 14:00, 17. Mai 2008 (CEST)C.J.17.05.2008
+
      protection network
 +
    * Electric power consumption: 540W (depending on the stipulation of electric supplies control modulo)
 +
    * Size: 460W × 210H × 437D mm
 +
    * Weight:40 Kilo(!)

Revision as of 12:54, 14 December 2008

Template:Nicht vorlagenkonform

== LUXMAN M-05

   * Continual effective output: A class 105W + 105W (8 Ω, 20Hz - 20kHz both ch simultaneous operation)
   * BTL connection effective output: AB class 400W (to 105W A class, 8 Ω, 20Hz - 20kHz)
   * Total height harmonic wave distortion factor: 0.008% (8 Ω, both ch simultaneous operation) 0.01% (4 Ω, both ch)
   * Cross modulation distortion factor: 0.008% (8 Ω, 60Hz: 7kHz = 4: 1)
   * Frequency characteristic: 10 - 100, 000Hz (- 0.5 dB)
   * Entry sensitivity: 750mV
   * Input impedance: DIRECT - IN 300k Ω, ATT - IN 45k Ω
   * Signal-noise ratio: 120 dB (IHF - A revision)
   * Attachment: The line phase sensor BTL connected SW sub sonic filter SW (15Hz)
     which the polarity of terminal signal OFF SW 3 step change FAN SW
     power source for the peak hold attaching peak meter (meter OFF SW
     The line phase sensor BTL connected SW sub sonic filter SW (15Hz)
     which can manage the polarity of 3 step change FAN SW power sources -
     6 dB/oct entry worm rise feature pre- heat Entry worm rise feature pre- heat feature
   * Protection network: DC drift detection speaker protection network overcurrent detection
     amplifier protection network temperature detection amplifier
     protection network
   * Electric power consumption: 540W (depending on the stipulation of electric supplies control modulo)
   * Size: 460W × 210H × 437D mm
   * Weight:40 Kilo(!)