Difference between revisions of "Grundig GCCM320"

 
Line 1: Line 1:
'''[[Grundig]] GCCM 320 Mono-Mikrofon'''
+
'''[[Grundig]] GCCM 320 mono microphone'''
  
* Wandler-Prinzip: Elektret-Kondensator-Mikrofon (2 getrennte Wandlersysteme)
+
* Transducer principle: electret condenser microphone (2 separate transducer systems)
* Richtcharakteristik: Umschaltbar Kugel - Niere
+
* Polar pattern: Switchable omnidirectional - cardioid
* Akustische Arbeitsweise: Kugel: Druckempfänger; Niere: Druckgradienten-Empfänger
+
* Acoustic mode of operation: Omnidirectional: pressure transducer; Cardioid: pressure gradient transducer.
* Anwendungsgebiet: Sprache und Musik; auch in Akustisch nicht ausgebauten Räumen. Bei paarweiser Verwendung auch für Stereo geeignet.
+
* Field of application: speech and music; also in acoustically undeveloped rooms. When used in pairs also suitable for stereo.
* Frequenzgang nach Sollkurve: +/ö 3 dB
+
* Frequency response according to nominal curve: +/- 3 dB
* Übertrsagungsbereich: 40 - 20.000 Hz
+
* Frequency response range: 40 - 20,000 Hz
* Auslöschung: > 15 dB
+
* Cancellation: > 15 dB
* Feld-Leerlauf-Übertragungsfaktor bei 1 kHz: >= 0,7 mV/µbar
+
* Field-to-noise transfer factor at 1 kHz: >= 0.7 mV/µbar
* Impedanz: 850 Ohm (Kugel); 1000 Ohm (Niere)
+
* Impedance: 850 Ohm (omnidirectional); 1000 Ohm (cardioid)
* Versorgungsspannung: 4,5 V ... 20 V
+
* Supply voltage: 4.5 V ... 20 V
* Stromaufnahme: <= 150 µA
+
* Current consumption: &lt;= 150 µA
* Anschluss an ein Tonbandgerät oder Cassetendeck über 5-poligen DIN-Stecker mit Mittelstift
+
* Connection to a tape recorder or cassette deck via 5-pin DIN connector with center pin
  
Mit Hilfe des Adapterkabels 278a können zwei GCCM 320 für Stereo-Aufnahmen verbunden werden. Zum Verlängern der Mikrofonleitungen dient das Verlängerungskabel 391.
+
Using the adapter cable 278a, two GCCM 320 can be connected for stereo recording. The extension cable 391 is used to extend the microphone cables.
  
[[Kategorie: Mikrofone]]
+
[[Category: Microphones]]
 +
 
 +
 
 +
 
 +
 
 +
[[Image:Grundig_GCCM_320.jpg]]

Latest revision as of 08:33, 28 December 2009

Grundig GCCM 320 mono microphone

  • Transducer principle: electret condenser microphone (2 separate transducer systems)
  • Polar pattern: Switchable omnidirectional - cardioid
  • Acoustic mode of operation: Omnidirectional: pressure transducer; Cardioid: pressure gradient transducer.
  • Field of application: speech and music; also in acoustically undeveloped rooms. When used in pairs also suitable for stereo.
  • Frequency response according to nominal curve: +/- 3 dB
  • Frequency response range: 40 - 20,000 Hz
  • Cancellation: > 15 dB
  • Field-to-noise transfer factor at 1 kHz: >= 0.7 mV/µbar
  • Impedance: 850 Ohm (omnidirectional); 1000 Ohm (cardioid)
  • Supply voltage: 4.5 V ... 20 V
  • Current consumption: <= 150 µA
  • Connection to a tape recorder or cassette deck via 5-pin DIN connector with center pin

Using the adapter cable 278a, two GCCM 320 can be connected for stereo recording. The extension cable 391 is used to extend the microphone cables.



Grundig GCCM 320.jpg