== Daten ==
+
__NOTOC__
{{Navigation}}
+
== Data ==
'''Allgemein'''
+
{{navigation}}
* Hersteller: [[Pioneer]]
+
'''General'''
* Modell: SD-1000 (in Japan SD-100)
+
* Manufacturer: [[Pioneer]]
* Baujahre: 1971 - 1972
+
* Model: SD-1000 (in Japan SD-100)
* Hergestellt in: Japan
+
* Type: Stereo Oscilloscope
* Farbe: Holz / Metall Silber / Anzeigen Plexiglas Schwarz
+
* Years of manufacture: 1971 - 1972
* Typ: Stereo Oszilloskop
+
* Made in: Japan
* Leistungsaufnahme: 25 Watt (max.)
+
* Color: Wood / Metal Silver / Displays Plexiglas Black
* Abmessungen: 430 x 145 x 348 mm (BxHxT)
+
* Type: Stereo Oscilloscope
* Gewicht: 8,8 kg.
+
* Power consumption: 25 watts (max.)
* Neupreis ca.: 108'000 Yen (Japan, 1971), 550 US-$ (~2200 DM)
+
* Dimensions: 430 x 145 x 348 mm (WxHxD)
 +
* Weight: 8.8 kg.
 +
* Original price approx.: 108'000 Yen (Japan, 1971), 550 US-$ (~2'200 DM)
  
  
'''Anschlüsse'''
+
'''Connections'''
* Anzahl der Eingänge:
+
* Number of inputs:
** Eingangsklemmen Front: 3
+
** Input terminals front: 3
*** Eingang 1 (Vertikal)
+
*** Input 1 (Vertical)
*** Eingang 2 (Horizontal)
+
*** Input 2 (Horizontal)
*** Mikrofon (Mono), Empfindlichkeit 0,6mV, 50 kOhm bei 1 kHz
+
*** Microphone (mono), sensitivity 0.6mV, 50 kOhm at 1 kHz
** Eingänge Hinten: 6
+
** Inputs Rear: 6
*** Eingänge 1, 2, 3, 4
+
*** Inputs 1, 2, 3, 4
*** UKW Multipath Vertikal
+
*** VHF Multipath Vertical
*** UKW Multipath Horizontal
+
*** FM Multipath Horizontal
* Anzahl der Ausgänge: 1
+
* Number of outputs: 1
** Ausgang Front: AF OSC Tongenerator
+
** Output Front: AF OSC Tone Generator
  
  
'''Technische Daten'''
+
'''Specifications'''
* Oszilloskop:
+
* Oscilloscope:
** Braun'sche Röhre 75mm (Elektrostatik Typ)
+
** Braun's tube 75mm (electrostatic type).
* Vertikale Ablenkung:
+
* Vertical deflection:
** Empfindlichkeit: 20 mV P-P/cm
+
** Sensitivity: 20 mV P-P/cm
** Frequenzumfang: 5Hz - 250kHz (< -3dB)  
+
** Frequency range: 5Hz - 250kHz (&lt; -3dB)  
** Eingangsimpedanz: 190kohm   
+
** Input impedance: 190kohm   
* Horizontal Ablenkung:
+
* Horizontal deflection:
** Empfindlichkeit: 20 mV P-P/cm
+
** Sensitivity: 20 mV P-P/cm
** Frequenzumfang: 5Hz - 250Hz (< -3dB)  
+
** Frequency range: 5Hz - 250Hz (< -3dB)  
 
** Eingangsimpedanz: 190kohm
 
** Eingangsimpedanz: 190kohm
 
* Frequenzamplitude des Abtastweges (4 Bereiche): 10Hz - 100kHz   
 
* Frequenzamplitude des Abtastweges (4 Bereiche): 10Hz - 100kHz   
* Synchronschaltung: > 3/8 Inch auf Bildschirm
+
* Synchronschaltung: >3/8 inch on screen
** Internes Synchronisierungssystem
+
** Internal synchronization system.
* Zusatzschaltung:
+
* Auxiliary circuit:
** Punkt-Killer Schaltung
+
** Point killer circuit
  
  
* Tongenerator:
+
* Tone generator:
** Frequenzbereich: 20 - 20000 Hz
+
** Frequency range: 20 - 20000 Hz
** Ausgangsspannung: 2V oder mehr, regelbar
+
** Output voltage: 2V or more, adjustable
** Frequenzgang: 20 - 20000 Hz, < ± 1 dB
+
** Frequency response: 20 - 20000 Hz, &lt; ± 1 dB
** Ausgangsimpedanz: < 4,7 kOhm
+
** Output impedance: &lt; 4.7 kOhm
** Harm. Verzerrung: < 1% (20 - 20000 Hz)
+
** Harm. Distortion: &lt; 1% (20 - 20000 Hz)
  
  
* Ausgangsmesser:
+
* Output meter:
** Referenzbereich: 0 dB bei 2V
+
** Reference range: 0 dB at 2V
** Eingangsempfindlichkeit, umschaltbar: 0 dB, -10 dB, -20 dB
+
** Input sensitivity, switchable: 0 dB, -10 dB, -20 dB
** Einstellzeit: < 0,3 Sekunden bei 0 dB, bei 1 kHz
+
** Response time: &lt; 0.3 seconds at 0 dB, at 1 kHz
** Frequenzumfang: 20 - 20000 Hz ± 1 dB
+
** Frequency range: 20 - 20000 Hz ± 1 dB
  
  
'''Besondere Ausstattungen'''
+
'''Special Features'''
* Mikrofonanschluss Front für Messmikrofon
+
* Microphone connector front for measuring microphone
* Pegelregler Rückseite für Bildröhren Fokus und Intensität
+
* Level control rear for picture tube focus and intensity
  
  
== Bemerkungen ==
+
== Remarks ==
* Die erste Version des klassischen (und seltenen) Test Instruments von Pioneer. Es integrierte ein Oszilloskop mit Waveform/Lissajous/FM-Multipath-Anzeige-Optionen und kombiniert das mit dualem (V/H oder L/R) Pegelmesser. Das SD-1000 ist nicht ganz so vielseitig in Quad-Display/Analyse-Funktionen wie die nächste Version SD-1100, aber es ist ein klassisches Design und ein sehr nützliches (und attraktives) Testinstrument.
+
* The first version of Pioneer's classic (and rare) Test Instrument. It integrated an oscilloscope with waveform/lissajous/FM multipath display options and combined that with dual (V/H or L/R) level meter. The SD-1000 isn't quite as versatile in quad-display/analysis features as the next version, SD-1100, but it's a classic design and a very useful (and attractive) test instrument.
* Das Gerät hat einen integrierten Frequenzgenerator, für Sweep und Sinus. 4 separat steuerbare Eingänge. Man kann sich Wellenformen anzeigen lassen.
+
* The unit has a built-in frequency generator, for sweep and sine. 4 separately controllable inputs. You can display waveforms.
* Die Pegelmesser sind in einem Pre-Silver Aera Farbschema von Grün/Orange mit einer schwarzen Faszie.
+
* The level meters are in a Pre-Silver Aera color scheme of green/orange with a black fascia.
* Das SD-1000 ist ein Stereo-Display-Gerät, das synthetisch akustische Eigenschaften wie verschiedene Wellen und auch Klangfeld-Eigenschaft eines hörenden Raumes beobachten und messen kann.
+
* The SD-1000 is a stereo display device that can synthetically observe and measure acoustic properties such as various waves and also sound field property of a listening room.
* Ein Tuner mit Multipath-Ausgang kann angeschlossen werden und die Ausrichtung der Antenne kann so leichter optimiert werden.
+
* A tuner with multipath output can be connected and antenna alignment can be optimized more easily.
* Zwei groß dimensionierte Pegelmesser sind für die Leistungs- und Spannungsmessung wie auch als VU-Pegel Messgerät einsetzbar.
+
* Two large dimension level meters can be used for power and voltage measurement as well as VU level meter.
* Die Eingangsklemme für 4-Kanal ist ebenfalls vorbereitet.
+
* Input terminal for 4-channel is also prepared.
* Das Gerät ist auch mit einem breitbandigen Frequenz Verstärker für ein Mono-Mikrofon ausgerüstet. Auf diese Weise können die Empfindlichkeit, der akustische Frequenzgang und die Merkmale des Lautsprechersystems mit einem Elektret-Kondensator-Mikrofon überprüft werden. Das Pioneer Mikrofon war optional als Typ Pioneer CM-01 erhältlich.
+
* The instrument is also equipped with a wideband frequency amplifier for a mono microphone. In this way, the sensitivity, acoustic frequency response and characteristics of the speaker system can be checked with an electret condenser microphone. The Pioneer microphone was optionally available as type Pioneer CM-01.
  
  
* Weitere Modelle der gleichen Serie:
+
* Other models in the same series:
** Pioneer SD-1100
+
* [[Pioneer SD-1000]]
*** [[Pioneer SD-1100|SD-1100]]
+
* [[Pioneer SD-1100]]
  
  
* Passende Verstärker Modelle der gleichen Serie:
+
* Matching amplifier models in the same series:
 
** [[Pioneer SA-600]]
 
** [[Pioneer SA-600]]
 
** [[Pioneer SA-800]]
 
** [[Pioneer SA-800]]
 
** [[Pioneer SA-1000]]
 
** [[Pioneer SA-1000]]
 
** [[Pioneer QA-800]]
 
** [[Pioneer QA-800]]
** [[Pioneer QC-000]]
+
** [[Pioneer QC-800]]
 
** [[Pioneer QM-800]]
 
** [[Pioneer QM-800]]
  
  
* Passende Tuner Modell:
+
* [[Matching Tuner Model]]
 
** [[Pioneer TX-600]]
 
** [[Pioneer TX-600]]
 
** [[Pioneer TX-800]]
 
** [[Pioneer TX-800]]
Line 97: Line 99:
  
  
== Bilder ==
+
== Pictures ==
* Bild: Pioneer Oszilloskop SD-1000 Front
+
* Image: Pioneer oscilloscope SD-1000 front
[[Datei:Pioneer SD-1000-1.jpg]]
+
[[File:Pioneer CM-01-2.jpg]]
  
  
* Bild: Pioneer Oszilloskop SD-1000 in Betrieb
+
* Image: Pioneer SD-1000 oscilloscope in operation.
[[Datei:Pioneer SD-1000-2.jpg]]
+
[[File:Pioneer SD-1000 Prospekt-3.jpg]]
  
  
* Bild: Optional Pioneer Elektret-Kondensator-Mikrofon CM-01
+
* Image: optional Pioneer CM-01 electret condenser microphone.
[[Datei:Pioneer CM-01-2.jpg]]
+
[[File:Pioneer CM-01-2.jpg]]
  
  
* Auszug aus Prospekt: Pioneer Oszilloskop SD-1000
+
* Excerpt from brochure: Pioneer SD-1000 oscilloscope
[[Datei:Pioneer SD-1000-Prospekt-3.jpg]]
+
[[File:Pioneer SD-1000 Prospekt-3.jpg]]
  
  
* Auszug aus Prospekt: Pioneer Oszilloskop SD-1000 Front Panel Ausstattung
+
* Excerpt from brochure: Pioneer Oscilloscope SD-1000 Front Panel Equipment.
[[Datei:Pioneer SD-1000-5.jpg]]
+
[[File:Pioneer SD-1000-5.jpg]]
  
  
* Bild: Pioneer Oszilloskop SD-1000 Rückseite
+
* Image: Pioneer Oscilloscope SD-1000 Rear Panel
[[Datei:Pioneer SD-1000-7.jpg]]
+
[[File:Pioneer SD-1000-7.jpg]]
  
  
== Berichte ==
+
== Reports ==
  
  
 
== Links ==
 
== Links ==
* Externer Link zum Download der Broschüre: [http://www.kallhovde.com/pioneer/sd-1000-b.pdf]
+
* External link to download the brochure: [http://www.kallhovde.com/pioneer/sd-1000-b.pdf]
  
* Externer Link: "Wegavision Pytalhost": [http://pioneer.pytalhost.eu/1972/pioneer72-22.jpg]
+
* External link: "Hifi Archive": [http://www.hifi-archiv.info/Pioneer/1972/pioneer72-22.jpg]
  
* Externer Link: "Pioneer Vintage": [http://www.pioneer-vintage.de/pioneer-components-ii/pioneer-scope/index.html]
+
* External Link: "Pioneer Vintage": [http://www.pioneer-vintage.de/pioneer-components-ii/pioneer-scope/index.html]
  
* Externer Link: "Audio Database, Japan": [http://audio-database.com/PIONEER-EXCLUSIVE/etc/sd-100-e.html]
+
* External link: "Audio Database, Japan": [http://audio-database.com/PIONEER-EXCLUSIVE/etc/sd-100-e.html]
  
Pioneer [[Pioneer Oszilloskope|Oszilloskope]]
+
 
 +
[[Category:Oscilloscopes]]</-3dB)>

Latest revision as of 05:29, 31 May 2020

Data[edit]

General

  • Manufacturer: Pioneer
  • Model: SD-1000 (in Japan SD-100)
  • Type: Stereo Oscilloscope
  • Years of manufacture: 1971 - 1972
  • Made in: Japan
  • Color: Wood / Metal Silver / Displays Plexiglas Black
  • Type: Stereo Oscilloscope
  • Power consumption: 25 watts (max.)
  • Dimensions: 430 x 145 x 348 mm (WxHxD)
  • Weight: 8.8 kg.
  • Original price approx.: 108'000 Yen (Japan, 1971), 550 US-$ (~2'200 DM)


Connections

  • Number of inputs:
    • Input terminals front: 3
      • Input 1 (Vertical)
      • Input 2 (Horizontal)
      • Microphone (mono), sensitivity 0.6mV, 50 kOhm at 1 kHz
    • Inputs Rear: 6
      • Inputs 1, 2, 3, 4
      • VHF Multipath Vertical
      • FM Multipath Horizontal
  • Number of outputs: 1
    • Output Front: AF OSC Tone Generator


Specifications

  • Oscilloscope:
    • Braun's tube 75mm (electrostatic type).
  • Vertical deflection:
    • Sensitivity: 20 mV P-P/cm
    • Frequency range: 5Hz - 250kHz (< -3dB)
    • Input impedance: 190kohm
  • Horizontal deflection:
    • Sensitivity: 20 mV P-P/cm
    • Frequency range: 5Hz - 250Hz (< -3dB)
    • Eingangsimpedanz: 190kohm
  • Frequenzamplitude des Abtastweges (4 Bereiche): 10Hz - 100kHz
  • Synchronschaltung: >3/8 inch on screen
    • Internal synchronization system.
  • Auxiliary circuit:
    • Point killer circuit


  • Tone generator:
    • Frequency range: 20 - 20000 Hz
    • Output voltage: 2V or more, adjustable
    • Frequency response: 20 - 20000 Hz, < ± 1 dB
    • Output impedance: < 4.7 kOhm
    • Harm. Distortion: < 1% (20 - 20000 Hz)


  • Output meter:
    • Reference range: 0 dB at 2V
    • Input sensitivity, switchable: 0 dB, -10 dB, -20 dB
    • Response time: < 0.3 seconds at 0 dB, at 1 kHz
    • Frequency range: 20 - 20000 Hz ± 1 dB


Special Features

  • Microphone connector front for measuring microphone
  • Level control rear for picture tube focus and intensity


Remarks[edit]

  • The first version of Pioneer's classic (and rare) Test Instrument. It integrated an oscilloscope with waveform/lissajous/FM multipath display options and combined that with dual (V/H or L/R) level meter. The SD-1000 isn't quite as versatile in quad-display/analysis features as the next version, SD-1100, but it's a classic design and a very useful (and attractive) test instrument.
  • The unit has a built-in frequency generator, for sweep and sine. 4 separately controllable inputs. You can display waveforms.
  • The level meters are in a Pre-Silver Aera color scheme of green/orange with a black fascia.
  • The SD-1000 is a stereo display device that can synthetically observe and measure acoustic properties such as various waves and also sound field property of a listening room.
  • A tuner with multipath output can be connected and antenna alignment can be optimized more easily.
  • Two large dimension level meters can be used for power and voltage measurement as well as VU level meter.
  • Input terminal for 4-channel is also prepared.
  • The instrument is also equipped with a wideband frequency amplifier for a mono microphone. In this way, the sensitivity, acoustic frequency response and characteristics of the speaker system can be checked with an electret condenser microphone. The Pioneer microphone was optionally available as type Pioneer CM-01.





Pictures[edit]

  • Image: Pioneer oscilloscope SD-1000 front

Pioneer CM-01-2.jpg


  • Image: Pioneer SD-1000 oscilloscope in operation.

Pioneer SD-1000 Prospekt-3.jpg


  • Image: optional Pioneer CM-01 electret condenser microphone.

Pioneer CM-01-2.jpg


  • Excerpt from brochure: Pioneer SD-1000 oscilloscope

Pioneer SD-1000 Prospekt-3.jpg


  • Excerpt from brochure: Pioneer Oscilloscope SD-1000 Front Panel Equipment.

Pioneer SD-1000-5.jpg


  • Image: Pioneer Oscilloscope SD-1000 Rear Panel

Pioneer SD-1000-7.jpg


Reports[edit]

Links[edit]

  • External link to download the brochure: [1]
  • External link: "Hifi Archive": [2]
  • External Link: "Pioneer Vintage": [3]